Metallized Polypropylene Film
AC Motor Start and Run Capacitors SMPA-UL Series
SSE SMPA Capacitor UL 810
Safety Standards
UL-810
Features
Long life due to self-healing characteristic.
High moisture resistance.
Very low loss at high frequency, suitable for high current.
Active and passive flame retardant (UL94 V-0).
Applications
AC Motor Start and Run Capacitors are widely used for electric motors starting or running such as air conditioner, refrigerator, washing machine, dishwasher, motor pump, bread maker, fan, electrical power tool, power supply, UPS, etc.
Specifications
Working Voltage Range Max. 460 VAC
Capacitance Range 0.01 ~ 90μF
Capacitance Tolerance J (±5%), U (+10-5%), K (±10%), M (±20%)
Temperature Range -40 ~ +85℃
Rated Working Frequency Range 50 ~ 60Hz
Dissipation Factor ≤ 1% Max. Measured at 1kHz 20℃
Between Terminals(T-T) Rated voltage x 175% VAC 10sec
Between Terminals and Case(T-C) 2000VAC, 60sec
Constructions of Winding Elements
Size Deviation
Size Deviation (Unit: mm)
SMPA CP Wire Sectional View
CP Wire Sectional View
SMPA Fast-on Terminal Sectional View
Fast-on Terminal Sectional View
SMPA Film Cross Sectional View
Film Cross Sectional View
Model and Type
Type→
Model↓
BX BL BF BU RO
A  
B
C  
D
E  
F  
G
H
I
J
Dimensions of Fast-on Terminals
Fast-on terminals
Terminal→
Dimensions↓
110 187 205 250 ±Tolerance
A 2.80 4.75 5.25 6.35 0.25
H 7.50 6.35 7.00 8.00 0.50
h 5.30 3.50 4.00 4.00 0.20
t 0.50 0.50 0.80 0.80 0.05
Ød 1.25 1.35 1.65 1.65 0.05
(Unit: mm)
Case Size List
Please download SMPA-UL catalog or contact us for more details.